Rudolf Scheidl, Christoph Gradl, Helmut Kogler, Paul Foschum, Andreas Plöckinger,
"Investigation of a Switch-Off Time Variation Problem of a Fast Switching Valve"
: Proceedings of the ASME/BATH 2014 Symposium on Fluid Power & Motion Control (FPMC2014), September 10-12, 2014, Bath, UK, Seite(n) FPMC2014-7851, 9-2014
Original Titel:
Investigation of a Switch-Off Time Variation Problem of a Fast Switching Valve
Sprache des Titels:
Englisch
Original Buchtitel:
Proceedings of the ASME/BATH 2014 Symposium on Fluid Power & Motion Control (FPMC2014), September 10-12, 2014, Bath, UK
Original Kurzfassung:
In a series of experiments the peak current during switch on of a fast switching valve, which was found to be out of tolerances with respect to some armature dimensions, was varied to realize different switch on times. Despite the fact that the holding current was identical for all cases and the time between switch on and off was very long, the valve?s switch off time showed an unexpected dependency on the switch on peak current value. This paper presents an explanation of this phenomenon by coarse mathematical models, demonstrating that the manufacturing error in combination with friction, skewness, and fluid stiction are responsible for this behavior.